- Date
- 08/11/2017
- W/O
- 646328
- Weather
- Dry
- Operator/Surveyor
- JUAN B
- Sewer ID
- Z00700
- PipeID
- P14781
- Time
- 3:27 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K4684
- Sewer Name
- 18 SCOTT AVENUE TRUNK
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- WO_646328_TV18118_JUL2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 18 0933
- Downstream MH
- 18 0932
- Dir. of Survey
- Downstream
- Length Surveyed
- 84.3 ft.
- Total Length
- 84.3 ft.
- Structural Index
- 4
- Structural Quick
- 5141
- Structural Rating
- 12
- O&M Index
- 3
- O&M Quick
- 4121
- O&M Rating
- 6
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 18
Pipe schematic from manhole 18 0933 to 18 0932 Observation photos (4)

2.1 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

4.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

4.5 ft. - Broken, from 03 to 05 o'clock, within 8 inches of joint: YES