- Date
- 06/30/2017
- W/O
- 640678
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z01125
- PipeID
- P13487
- Time
- 1:54 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4634
- Sewer Name
- B JOINT OUTFALL B - UNIT 6H
- City
- SOUTH PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- WO_640678_TV16072_JUN2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- B 1167
- Downstream MH
- B 1166
- Dir. of Survey
- Downstream
- Length Surveyed
- 261.9 ft.
- Total Length
- 261.9 ft.
- Structural Index
- 2
- Structural Quick
- 2100
- Structural Rating
- 2
- O&M Index
- 2
- O&M Quick
- 2F00
- O&M Rating
- 72
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 74
Pipe schematic from manhole B 1167 to B 1166 Observation photos (2)

81.5 ft. - Deposits Settled Fine, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

143.3 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES