- Date
- 07/06/2017
- W/O
- 640678
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z01125
- PipeID
- P13172
- Time
- 1:33 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4635
- Sewer Name
- B JOINT OUTFALL B - UNIT 6H
- City
- ALHAMBRA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- WO_640678_TV16072_JUN2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- B 1132
- Downstream MH
- B 1131
- Dir. of Survey
- Downstream
- Length Surveyed
- 244.4 ft.
- Total Length
- 244.4 ft.
- Structural Index
- 3
- Structural Quick
- 3H00
- Structural Rating
- 141
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 141
Pipe schematic from manhole B 1132 to B 1131 Observation photos (2)

4.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

189.7 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"