Section#5_08 0468_08 0467__922017__G6815.mp4
2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES
2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG % CURCUM REBAR AREAS OF MISSING TILES
2 ft. - General Observation - MISSING TILES 60% START
2.1 ft. - Deposits Settled Other, 70 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start - TILES
17.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR MISSING
25.6 ft. - General Observation - MISSING TLES 30% START
78.4 ft. - Surface Reinforcement Corroded, from 01 to 02 o'clock, within 8 inches of joint: NO - LONG REBAR
89.4 ft. - General Observation - 100% MISSING TILES
105.1 ft. - General Observation - 100% MISSING TILES
121.2 ft. - General Observation - MISSING TILES 90% START
176.9 ft. - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO
243.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
288.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - BROKEN
323.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING
354.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO
371.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING
380.2 ft. - General Photograph
411 ft. - Deposits Settled Other, 70 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish - TILES
442.4 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish
| Distance | Code | Observation |
|---|---|---|
| 288.6 | SRC | BROKEN |
| 2 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 17.1 | SRC | CIRCUM REBAR MISSING |
| 243.3 | SRC | BROKEN MISSING REBAR |
| 121.2 | MGO | MISSING TILES 90% START |
| 442.4 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 2 | SRC | LONG % CURCUM REBAR AREAS OF MISSING TILES |
| 354.5 | SRC | — |
| 442.4 | SRC | — |
| 442.9 | AMH | 8:35AM |
| 2 | MGO | MISSING TILES 60% START |
| 176.9 | SRC | — |
| 0 | MWM | — |
| 25.6 | MGO | MISSING TLES 30% START |
| 0 | AMH | 8:10AM |
| 380.2 | MGP | — |
| 89.4 | MGO | 100% MISSING TILES |
| 105.1 | MGO | 100% MISSING TILES |
| 442.4 | MGO | MISSING TILES 90% FINISH |
| 2.1 | DSZ | TILES |
| 371.1 | SRC | BROKEN MISSING |
| 0 | MWL | — |
| 0 | MGO | MH CONN OPEN 3:00 |
| 411 | DSZ | TILES |
| 78.4 | SRC | LONG REBAR |
| 323.6 | SRC | BROKEN MISSING |