Section#1_08 0472_08 0606__922017__G6814.mp4
2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
6.1 ft. - Lining Change, Other ) - TILES LINE 100% INTACT
10.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
10.2 ft. - General Observation - MISSING TILE 100% START
10.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR CORRODED & MISSING
14.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR MISSING & CORRODED
14.2 ft. - General Observation - 10% TILES '
19.1 ft. - General Observation - UNUSAL STOPLOG IN PLACE DOWNSTREAM
| Distance | Code | Observation |
|---|---|---|
| 19.6 | AMH | 1:40AM |
| 19.1 | SRC | CIRCUM REBAR AREAS OF MISSING TILES |
| 14.2 | SRC | CIRCUM REBAR MISSING & CORRODED |
| 14.2 | MGO | 10% TILES ' |
| 19.1 | MGO | UNUSAL STOPLOG IN PLACE DOWNSTREAM |
| 2 | SRC | CIRCUM REBAR |
| 10.2 | SRC | CIRCUM REBAR |
| 10.2 | MGO | MISSING TILE 100% START |
| 19.1 | SAM | SEVERE AGG SREAS OF MISSING TILES |
| 2 | SAM | SEVERE AGG |
| 0 | MWL | — |
| 0 | AMH | 1:15AM |
| 0 | MWM | — |
| 10.2 | SRC | CIRCUM REBAR CORRODED & MISSING |
| 6.1 | MLC | TILES LINE 100% INTACT |