Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 17, 2017, 09:52 AM
  • 02 0886_02 0885 _17072017_025442.mp4

Date
07/17/2017
W/O
646417
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00249
PipeID
P03454
Time
2:52 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4652
Sewer Name
02 DOWNEY TRUNK
City
DOWNEY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_646417_TV02050_JUL2017
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 0885
Downstream MH
02 0886
Dir. of Survey
Upstream
Length Surveyed
228.6 ft.
Total Length
228.6 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
135
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
137
Pipe schematic from manhole 02 0885 to 02 0886
MH: 02 0885MH: 02 0886upstream0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 02 088675 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"76 ft. TBI - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 2"83.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"127.8 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"223.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start226.5 ft. MGO - General Observation - mag coat228.6 ft. AMH - Downstream Manhole, Survey Begins - 02 0885228.6 ft. MWL - Water Level, 10 %of cross sectional area228.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK228.6 ft. MWM - Water Mark, 25 %of cross sectional area

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 2"

    152.6 ft. - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 2"

Observations (12)

DistanceCodeObservation
0AMH02 0885
145.2TF
153.6TFC
5.3SAV
228.6SAV
100.8TF
0MWL
152.6TBI
2.1MGOmag coat
0MGOCONNECTION AT MH 3 O'CLOCK
228.6AMH02 0886
0MWM

Properties (5)

additional_info
SC345512
custom_field_two
3
customer
LACSD
datetime
2017-07-17T02:52:45-07:00
sewer_category
Gravity