Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2017, 05:56 AM
  • F 0079_F 0078 _12072017_225722.mp4

Date
07/12/2017
W/O
640863
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00043
PipeID
P10283
Time
10:56 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4644
Sewer Name
F JOINT OUTFALL F - UNIT 7A
City
CERRITOS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
WO_640863_TV02203_JUN2017
Material
Reinforced Concrete Pipe
Shape
Circular
Height
60 in.
Width
60 in.
Upstream MH
F 0079
Downstream MH
F 0078
Dir. of Survey
Downstream
Length Surveyed
696.2 ft.
Total Length
696.2 ft.
Structural Index
3
Structural Quick
3Z00
Structural Rating
411
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
411
Pipe schematic from manhole F 0079 to F 0078
MH: F 0079MH: F 0078downstream0 ft. AMH - Upstream Manhole, Survey Begins - F 00790 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area9.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start695 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish696 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK696.2 ft. AMH - Downstream Manhole, Survey Ends - F 0078

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    9.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
696MGOCONNECTION AT MH 9 O'CLOCK
696.2AMHF 0078
9.8SAP
0AMHF 0079
0MWL
695SAP
0MWM

Properties (5)

additional_info
SC345504
custom_field_two
2
customer
LACSD
datetime
2017-07-12T22:56:01-07:00
sewer_category
Gravity