Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2016, 09:15 AM
  • 18 0032_18 0031_042716_021633.mpg

Date
04/27/2016
W/O
568736
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00713
PipeID
P13848
Time
2:15 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3330
Sewer Name
18 WALNUT WAY TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
15
Purpose
Routine Assessment
Project
WO_568736_TV18059_MAY2016
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
18 0032
Downstream MH
18 0031
Dir. of Survey
Downstream
Length Surveyed
320.3 ft.
Total Length
320.3 ft.
Structural Index
3
Structural Quick
3L21
Structural Rating
194
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
194
Pipe schematic from manhole 18 0032 to 18 0031
MH: 18 0032MH: 18 0031downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 00322 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.4 ft. MGO - General Observation - MAG COAT 10%44.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"80.2 ft. CM - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES90.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"309 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES318 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish320.3 ft. AMH - Downstream Manhole, Survey Ends - 18 0031320.3 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK

Observation photos (2)

  • Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

    80.2 ft. - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    309 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
320.3AMH18 0031
0MWL
80.2CM
0MWM
309CL
2.4MGOMAG COAT 10%
2SAV
90.9TF
320.3MGOCONNECTION AT MH 9 OCLOCK
0AMH18 0032
44.8TFC
318SAV

Properties (5)

additional_info
SC226000
custom_field_two
3
customer
LACSD
datetime
2016-04-27T02:15:58-07:00
sewer_category
GRAVITY