Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 28, 2016, 10:07 AM
  • 18 0002_18 0001_042816_030735.mpg

Date
04/28/2016
W/O
568736
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00713
PipeID
P13817
Time
3:07 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3356
Sewer Name
18 WALNUT WAY TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_568736_TV18059_MAY2016
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
18 0002
Downstream MH
18 0001
Dir. of Survey
Downstream
Length Surveyed
355.9 ft.
Total Length
355.9 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 18 0002 to 18 0001
MH: 18 0002MH: 18 0001downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 00020 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start19.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"50 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"107.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"117.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"149.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"201.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"225.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"247.2 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES250 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"292.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"330.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"346.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"355.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish355.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0001

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    247.2 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
355.9SAV
201.4TF
346.5TF
330.7TF
50TF
0AMH18 0002
19.6TF
2.6SAV
0MWL
225.7TF
292.5TF
117.5TF
107.6TF
250TF
247.2CL
355.9AMH18 0001
0MWM
149.9TF

Properties (5)

additional_info
SC300352
custom_field_two
3
customer
LACSD
datetime
2016-04-28T03:07:04-07:00
sewer_category