- Date
- 08/25/2017
- W/O
- 0651131
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z01145
- PipeID
- P25708
- Time
- 4:27 PM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G6811
- Sewer Name
- 05 MANCHESTER AVENUE PUMP RELIEF TRUNK
- City
- GARDENA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 14
- Purpose
- Maintenance Related
- Project
- 20170824AM_MANCHESTER_AVENUE_PUMP_RELIEF_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- 05 2616
- Downstream MH
- 05 2617
- Dir. of Survey
- Upstream
- Length Surveyed
- 126.3 ft.
- Total Length
- 126.3 ft.
- Structural Index
- 2
- Structural Quick
- 2D00
- Structural Rating
- 48
- O&M Index
- 2
- O&M Quick
- 5141
- O&M Rating
- 45
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 93
Pipe schematic from manhole 05 2616 to 05 2617 Observation photos (4)

5.1 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

35.6 ft. - Deposits Settled Other, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start - DEBRIS

104.3 ft. - General Observation - SEVERE SPALLING