Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 15, 2017, 04:34 PM
  • 29 0574_29 0573 _20170615_094320.mp4

Date
06/15/2017
W/O
641199
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01117
PipeID
P24819
Time
9:34 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4620
Sewer Name
29 REDONDO AVENUE SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
WO_641199_TV29027_JUN2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0574
Downstream MH
29 0573
Dir. of Survey
Downstream
Length Surveyed
147.1 ft.
Total Length
147.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 29 0574 to 29 0573
MH: 29 0574MH: 29 0573downstream0 ft. AMH - Upstream Manhole, Survey Begins - 29 05740 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area5.7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start7.6 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"39.8 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"47.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"85.9 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"94 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"131.8 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish147.1 ft. AMH - Downstream Manhole, Survey Ends - 29 0573

Observation photos (1)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    5.7 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
5.7DAE
7.6TF
0AMH29 0574
131.8DAE
94TF
147.1AMH29 0573
0MWL
47.8TF
0MWM
39.8TF
85.9TF

Properties (5)

additional_info
SC345334
custom_field_two
4
customer
LACSD
datetime
2017-06-15T09:34:37-07:00
sewer_category
Gravity