- Date
- 08/12/2017
- W/O
- 0646419
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00048
- PipeID
- P10342
- Time
- 1:13 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G6799
- Sewer Name
- F JOINT OUTFALL F - UNIT 7F
- City
- CERRITOS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 38
- Purpose
- Capital Improvement Program Assesment
- Project
- 20170812MDM_JOINT_OUTFALL_F_UNIT_7F
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 33 in.
- Upstream MH
- F 0211A
- Downstream MH
- F 0211
- Dir. of Survey
- Downstream
- Length Surveyed
- 134.6 ft.
- Total Length
- 134.6 ft.
- Structural Index
- 2
- Structural Quick
- 2D00
- Structural Rating
- 52
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 52
Pipe schematic from manhole F 0211A to F 0211 Observation photos (4)

0 ft. - General Observation - MAG COAT 98% 8:00 TO 4:00 START

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLIOSTERING PEELING CONCRETE

64.5 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE POSSIBLE MINERIAL DEPOSITS AROUND

108.8 ft. - General Photograph