- Date
- 07/10/2017
- W/O
- 640621
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00941
- PipeID
- P11123
- Time
- 11:35 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4604
- Sewer Name
- H JOINT OUTFALL H - UNIT 9B
- City
- LA PUENTE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 29
- Purpose
- Routine Assessment
- Project
- WO_640621_TV15078_JUN2017
- Material
- NRCP
- Shape
- Circular
- Height
- 25 in.
- Width
- 25 in.
- Upstream MH
- H 0715
- Downstream MH
- H 0714
- Dir. of Survey
- Downstream
- Length Surveyed
- 1010.7 ft.
- Total Length
- 1010.7 ft.
- Structural Index
- 2
- Structural Quick
- 3G2g
- Structural Rating
- 527
- O&M Index
- 2
- O&M Quick
- 2g00
- O&M Rating
- 404
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 931
Pipe schematic from manhole H 0715 to H 0714 Observation photos (5)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

769.5 ft. - Material Change, Polyvinyl Chloride (PVC)

781.7 ft. - Material Change, Concrete pipe (non-reinfored) - NRCP

807.2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start