Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 27, 2017, 07:21 AM
  • 15 0126_15 0125 _27062017_003253.mp4

Date
06/27/2017
W/O
624421
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00634
PipeID
P12025
Time
12:21 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4594
Sewer Name
15 TYLER AVENUE TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
23
Purpose
Routine Assessment
Project
WO_624421_TV15037_JUN2017
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0126
Downstream MH
15 0125
Dir. of Survey
Downstream
Length Surveyed
154.8 ft.
Total Length
154.8 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
412E
O&M Rating
64
Overall Index
2
Overall Quick
Overall Rating
70
Pipe schematic from manhole 15 0126 to 15 0125
MH: 15 0126MH: 15 0125downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 01262 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start12.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"15.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"55.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"70.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"83.4 ft. MGO - General Observation - 60% MAG COATING153.8 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish153.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish154.8 ft. MGO - General Observation - ACTIVE CONNECTIONS AT MH 3 AND 9 O'CLOCK154.8 ft. AMH - Downstream Manhole, Survey Ends - 15 0125154.8 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (3)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    154.8 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (15)

DistanceCodeObservation
153.8SAV
154.8MGOACTIVE CONNECTIONS AT MH 3 AND 9 O'CLOCK
0MWL
70.8TFC
0MWM
2SAV
154.8AMH15 0125
55.6TF
83.4MGO60% MAG COATING
15.8TFA
0AMH15 0126
2DAGS
12.6TFC
153.8DAGS
154.8MGOCOCKROACHES IN MANHOLE

Properties (5)

additional_info
SC345342
custom_field_two
3
customer
LACSD
datetime
2017-06-27T00:21:42-07:00
sewer_category
Gravity