Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 20, 2017, 10:04 AM
  • 15 0133_15 0132 _20062017_031813.mpg

Date
06/20/2017
W/O
624421
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00634
PipeID
P12032
Time
3:04 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4622
Sewer Name
15 TYLER AVENUE TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
23
Purpose
Routine Assessment
Project
WO_624421_TV15037_JUN2017
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0133
Downstream MH
15 0132
Dir. of Survey
Downstream
Length Surveyed
383.9 ft.
Total Length
383.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 15 0133 to 15 0132
MH: 15 0133MH: 15 0132downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 01332.1 ft. MGO - General Observation - MAG COAT2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start21.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"137.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"254 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"326.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES327.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"383.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish383.9 ft. AMH - Downstream Manhole, Survey Ends - 15 0132

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    326.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
383.9SAV
0MWM
326.2DAGS
254TF
21.1TFA
0MWL
0AMH15 0133
327.8TFA
383.9AMH15 0132
137.4TFA
2.1MGOMAG COAT
2.1SAV

Properties (5)

additional_info
SC345337
custom_field_two
3
customer
LACSD
datetime
2017-06-20T03:04:28-07:00
sewer_category
Gravity