Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 7, 2017, 07:32 AM
  • H 0747_H 0746A_07072017_005843.mp4

Date
07/07/2017
W/O
640626
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00941
PipeID
P23488
Time
12:32 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4553
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
30
Purpose
Routine Assessment
Project
WO_640626_TV22077_JUN2017
Material
NRCP
Shape
Circular
Height
22 in.
Width
22 in.
Upstream MH
H 0747
Downstream MH
H 0746A
Dir. of Survey
Downstream
Length Surveyed
770.7 ft.
Total Length
770.7 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole H 0747 to H 0746A
MH: H 0747MH: H 0746Adownstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 07470 ft. MWL - Water Level, 15 %of cross sectional area2.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.8 ft. MGO - General Observation - MAG COATING3.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start101.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start770.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish770.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish770.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish770.7 ft. AMH - Downstream Manhole, Survey Ends - H 0746A

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    101.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
770.6SSS
0MWM
0AMHH 0747
3.8MGOMAG COATING
3.8SSS
0MWL
2.6DAGS
770.7AMHH 0746A
101.1SAV
770.5DAGS
770.6SAV

Properties (5)

additional_info
SC345391
custom_field_two
3
customer
LACSD
datetime
2017-07-07T00:32:24-07:00
sewer_category