- Date
- 03/08/2017
- W/O
- 624437
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00695
- PipeID
- P14012
- Time
- 11:41 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4316
- Sewer Name
- 18 ORR AND DAY ROAD TRUNK
- City
- SANTA FE SPRINGS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 19
- Purpose
- Routine Assessment
- Project
- WO_624437_TV18043_MAR2017
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Width
- 30 in.
- Upstream MH
- 18 0187
- Downstream MH
- 18 0186
- Dir. of Survey
- Downstream
- Length Surveyed
- 488.6 ft.
- Total Length
- 488.6 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2R00
- O&M Rating
- 194
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 194
Pipe schematic from manhole 18 0187 to 18 0186 Observation photos (2)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start