Section#2_05 2616_05 2615__8232017__G6808.mp4
5 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
230.2 ft. - Hole, from 09 to 10 o'clock, within 8 inches of joint: YES - POSSIBLE CEMENT SLURRY IN HOLE
258 ft. - General Photograph - HUGE AMOUNTS OF SPALLING/MISSING PIPE
286.9 ft. - Hole Soil Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
297.1 ft. - General Photograph - HOLE WITH POSSIBLE SOIL VISIBLE
326.1 ft. - Hole, from 09 to 03 o'clock, within 8 inches of joint: YES - VOID W/ CEMENT ENCASEMENT VISIBLE
332.4 ft. - Deposits Settled Other, 45 %of cross sectional area, from 02 to 06 o'clock, , within 8 inches of joint: YES - PIECES OF VCP
335 ft. - General Photograph - MORE OF THE DEBRIS 45%
| Distance | Code | Observation |
|---|---|---|
| 258 | MGP | HUGE AMOUNTS OF SPALLING/MISSING PIPE |
| 286.9 | HSV | — |
| 0 | AMH | 0100 |
| 300 | HSV | — |
| 335 | SSS | — |
| 332.4 | DSZ | PIECES OF VCP |
| 0 | MWL | — |
| 5 | SSS | — |
| 335 | MGP | MORE OF THE DEBRIS 45% |
| 297.1 | MGP | HOLE WITH POSSIBLE SOIL VISIBLE |
| 326.1 | H | VOID W/ CEMENT ENCASEMENT VISIBLE |
| 0 | MWM | — |
| 332.1 | H | — |
| 335 | MSA | TOO MUCH DEBRIS/PIECES OF PIPE IN THE LINE |
| 230.2 | H | POSSIBLE CEMENT SLURRY IN HOLE |