Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 19, 2017, 07:54 AM
  • 05 1860_05 1859_8192017_032750.mp4

Date
08/19/2017
W/O
0652016
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00490
PipeID
P07085
Time
12:54 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0615
Sewer Name
05 NARBONNE AVENUE TRUNK, SECTION 1(EAST)
City
LOMITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
35
Purpose
Capital Improvement Program Assesment
Project
20170818VMR_NARBONNE _AVE_TRUNK_SECTION_1_EAST
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
05 1860
Downstream MH
05 1859
Dir. of Survey
Downstream
Length Surveyed
340.8 ft.
Total Length
340.8 ft.
Structural Index
2
Structural Quick
2111
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 1860 to 05 1859
MH: 05 1860MH: 05 1859downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 03:00 am0 ft. MWL - Water Level, 10 %of cross sectional area17.3 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 4"17.7 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES25.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 4"62.5 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 4"88.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 4"136.7 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"187.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"238.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"278.8 ft. CC - Crack Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES286.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"340.8 ft. AMH - Downstream Manhole, Survey Ends - 3:45 am

Observations (14)

DistanceCodeObservation
0MWM
136.7TFC
25.3TF
238.4TFC
187.2TFC
286.4TF
278.8CC
340.8AMH3:45 am
17.3TB
0AMH03:00 am
0MWL
62.5TB
17.7CL
88.7TF

Properties (3)

custom_field_two
4
customer
LACSD
datetime
2017-08-19T00:54:05-07:00