- Date
- 06/28/2017
- W/O
- 640684
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00206
- PipeID
- P01034
- Time
- 10:56 PM
- Certificate
- U-115-06022794
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3976-SC342139
- Sewer Name
- 01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
- City
- LOS ANGELES
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- WO_640684_TV01243_JUN2017
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 01 0325A
- Downstream MH
- 01 0545
- Dir. of Survey
- Downstream
- Length Surveyed
- 11.9 ft.
- Total Length
- 11.9 ft.
- Structural Index
- 3
- Structural Quick
- 4132
- Structural Rating
- 10
- O&M Index
- 3
- O&M Quick
- 4122
- O&M Rating
- 8
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 18
Pipe schematic from manhole 01 0325A to 01 0545 Observation photos (3)

0.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

1.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

3.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start