Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 26, 2017, 08:36 AM
  • 01 0553_01 0552_26062017_025522.mp4

Date
06/26/2017
W/O
640684
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00206
PipeID
P01042
Time
1:36 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3975-SC342136
Sewer Name
01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Routine Assessment
Project
WO_640684_TV01243_JUN2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
01 0553
Downstream MH
01 0552
Dir. of Survey
Downstream
Length Surveyed
303.5 ft.
Total Length
303.5 ft.
Structural Index
4
Structural Quick
4K00
Structural Rating
240
O&M Index
2
O&M Quick
412K
O&M Rating
124
Overall Index
3
Overall Quick
Overall Rating
364
Pipe schematic from manhole 01 0553 to 01 0552
MH: 01 0553MH: 01 0552downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 05530 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start3.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start22.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"58.7 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 8"88.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"100.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"137.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"155 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"208.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"262.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"264.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"301.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish301.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish303.3 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK303.5 ft. AMH - Downstream Manhole, Survey Ends - 01 0552

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (18)

DistanceCodeObservation
100.3TB
264.4TFC
0AMH01 0553
301.6FM
301.6DAGS
262.1TFC
303.5AMH01 0552
208.7TF
22.9TB
137.7TFC
88.3TF
303.3MGOCONNECTION AT THE MH 9 O'CLOCK
58.7TB
3.9FM
3DAGS
155TFC
0MWM
0MWL

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2017-06-26T01:36:08-07:00