- Date
- 06/13/2017
- W/O
- 640960
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00750
- PipeID
- P19179
- Time
- 11:21 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4581
- Sewer Name
- 20 20TH STREET EAST TRUNK
- City
- PALMDALE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 20
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- WO_640960_TV20003_JUN2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 10 in.
- Width
- 10 in.
- Upstream MH
- 20 0212
- Downstream MH
- 20 0211
- Dir. of Survey
- Downstream
- Length Surveyed
- 271 ft.
- Total Length
- 271 ft.
- Structural Index
- 3
- Structural Quick
- 3A00
- Structural Rating
- 30
- O&M Index
- 2
- O&M Quick
- 2J00
- O&M Rating
- 108
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 138
Pipe schematic from manhole 20 0212 to 20 0211 Observation photos (4)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

184.7 ft. - Deposits Attached Grease, 10 %of cross sectional area, at 09 o'clock, , within 8 inches of joint: YES

204.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

222.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start