Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 8, 2017, 10:05 AM
  • 15 0724_15 0723 _08062017_041514.mp4

Date
06/08/2017
W/O
640731
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00616
PipeID
P12617
Time
3:05 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4545
Sewer Name
15 MONROVIA OUTFALL TRUNK
City
MONROVIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
09
Purpose
Routine Assessment
Project
WO_640731_TV15131_JUN2017
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
15 0724
Downstream MH
15 0723
Dir. of Survey
Downstream
Length Surveyed
163.9 ft.
Total Length
163.9 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
96
O&M Index
2
O&M Quick
2E11
O&M Rating
65
Overall Index
2
Overall Quick
Overall Rating
161
Pipe schematic from manhole 15 0724 to 15 0723
MH: 15 0724MH: 15 0723downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 07240 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT 9 OC3 ft. MGO - General Observation - MAG COATING3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start14.5 ft. VC - Vermin Cockroach163.8 ft. MGO - General Observation - CONNECTION AT 3 OC163.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish163.9 ft. AMH - Downstream Manhole, Survey Ends - 15 0723163.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0AMH15 0724
163.9DAGS
3MGOMAG COATING
163.9AMH15 0723
163.8MGOCONNECTION AT 3 OC
0MWM
3DAGS
0MWL
3SAV
0MGOCONNECTION AT 9 OC
14.5VC
163.9SAV

Properties (5)

additional_info
SC345360
custom_field_two
3
customer
LACSD
datetime
2017-06-08T03:05:21-07:00
sewer_category
Gravity