- Date
- 06/15/2016
- W/O
- 574627
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00325
- PipeID
- P08314
- Time
- 1:47 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3531
- Sewer Name
- A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
- City
- EL MONTE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 16
- Purpose
- Routine Assessment
- Project
- WO_574627_TV15209_JUNE2016
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Width
- 36 in.
- Upstream MH
- A 0814
- Downstream MH
- A 0813
- Dir. of Survey
- Downstream
- Length Surveyed
- 147.9 ft.
- Total Length
- 147.9 ft.
- Structural Index
- 3
- Structural Quick
- 3E2D
- Structural Rating
- 136
- O&M Index
- 2
- O&M Quick
- 412E
- O&M Rating
- 60
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 196
Pipe schematic from manhole A 0814 to A 0813 Observation photos (4)

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

16.2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

144.3 ft. - General Observation - COCKROACHES IN MANHOLE