Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 31, 2016, 08:51 AM
  • 14 0459_14 0458_31052016_015150.mp4

Date
05/31/2016
W/O
574295
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00570
PipeID
P18547
Time
1:51 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3515
Sewer Name
14 AVENUE "I" TRUNK
City
LANCASTER
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
04
Purpose
V
Project
WO_574295_TV14045_JUNE2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
14 0459
Downstream MH
14 0458
Dir. of Survey
Downstream
Length Surveyed
347.2 ft.
Total Length
347.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
512M
O&M Rating
143
Overall Index
2
Overall Quick
Overall Rating
143
Pipe schematic from manhole 14 0459 to 14 0458
MH: 14 0459MH: 14 0458downstream0 ft. MWM - Water Mark, 75 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 04590 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start7.6 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"58.9 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"61.5 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"109.2 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"112.2 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"160 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"162.5 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"207.3 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"209.9 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"257.7 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"260.3 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"311.6 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"314.1 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"343.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"346.2 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"347.2 ft. MSA - Survey Abandoned - REVERSAL COMPLETE.347.2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (3)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 10 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"

    346.2 ft. - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"

Observations (23)

DistanceCodeObservation
0MWM
0AMH14 0459
207.3TF
160TFC
343.7TF
109.2TFC
7.6TFA
314.1TFC
58.9TFC
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
0MWL
257.7TFC
346.2TFC
209.9TFA
260.3TFC
347.2MSAREVERSAL COMPLETE.
347.2DAGS
311.6TFA
162.5TFA
61.5TFC
112.2TFC
2DAGS
0MGOCOCKROACHES IN MANHOLE

Properties (5)

additional_info
SC305645
custom_field_two
4
customer
LACSD
datetime
2016-05-31T01:51:20-07:00
sewer_category