Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 15, 2016, 09:39 AM
  • 05 1661_05 1660 _061516_023940.mpg

Date
06/15/2016
W/O
563399
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00539
PipeID
P06885
Time
2:39 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3397
Sewer Name
05 WEST TORRANCE TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
33
Purpose
Routine Assessment
Project
WO_563399_TV05132_JUNE2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1661
Downstream MH
05 1660
Dir. of Survey
Downstream
Length Surveyed
261.2 ft.
Total Length
261.2 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
87
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
87
Pipe schematic from manhole 05 1661 to 05 1660
MH: 05 1661MH: 05 1660downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 16610 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - PIPE IS 18"0 ft. MWL - Water Level, 5 %of cross sectional area33.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES54.1 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"111.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"113 ft. CM - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES116.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start162.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"215.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"253.3 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish261.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1660261.2 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK

Observation photos (4)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    33.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    54.1 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

    113 ft. - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    116.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
261.2AMH05 1660
261.2MGOCONNECTION AT THE MH 9 O'CLOCK
116.4CM
0AMH05 1661
162.7TF
215.4TFC
0MWM
111.3TFC
54.1TB
0MGOPIPE IS 18"
113CM
253.3CM
0MWL
33.1CM

Properties (5)

additional_info
SC300397
custom_field_two
3
customer
LACSD
datetime
2016-06-15T02:39:05-07:00
sewer_category
Gravity