02 0808_02 0807_20160722_000407.mp4
0 ft. - Water Mark, 20 %of cross sectional area
5.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
8.7 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start
8.7 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
71.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
203.2 ft. - Crack Spiral, from 07 to 12 o'clock, within 8 inches of joint: YES
266.5 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES
275.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
321.2 ft. - Downstream Manhole, Survey Ends - 02 0807
| Distance | Code | Observation |
|---|---|---|
| 298.8 | TFC | — |
| 244 | TFC | — |
| 95.2 | TFC | — |
| 246.9 | TFC | — |
| 141 | TFC | — |
| 0 | MWL | — |
| 144.4 | TFC | — |
| 160.9 | CM | — |
| 266.5 | CL | — |
| 79.9 | TF | — |
| 295.7 | TFC | — |
| 23.1 | CL | — |
| 0 | AMH | 02 0808 |
| 8.7 | SSS | — |
| 71.4 | CM | — |
| 90.5 | SSS | — |
| 321.2 | AMH | 02 0807 |
| 8.7 | CL | — |
| 192.5 | TFC | — |
| 90.5 | CL | — |
| 195.4 | TFC | — |
| 45 | CM | — |
| 315.3 | CM | — |
| 222 | CM | — |
| 203.2 | CS | — |
| 275.5 | CM | — |
| 45.9 | TFC | — |
| 318.4 | DAGS | — |
| 126.8 | CM | — |
| 5.8 | DAGS | — |
| 0 | MWM | — |