Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 6, 2016, 11:45 AM
  • 01 0164_01 0163_06092016_044604.mp4

Date
09/06/2016
W/O
585995
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01190
Time
4:45 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3579
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
WO_585995_TV01012_AUG2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0164
Downstream MH
01 0163
Dir. of Survey
Downstream
Length Surveyed
327.1 ft.
Total Length
327.2 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 01 0164 to 01 0163
MH: 01 0164MH: 01 0163downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 01640 ft. MGO - General Observation - CAPPED LATERAL 9 O'CLOCK @ MH0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK0 ft. MWL - Water Level, 5 %of cross sectional area33.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"46 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"73 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"95.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"100.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"119.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"120.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"123.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"137 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"138.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"169.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"171.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"194.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"197.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"222.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"243.1 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES244.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"250.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"270.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"273.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"297 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"298.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"327.1 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK327.1 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK327.2 ft. AMH - Downstream Manhole, Survey Ends - 01 0163

Observation photos (3)

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    100.7 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    119.3 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    243.1 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

Observations (30)

DistanceCodeObservation
0AMH01 0164
95.7TFC
273.7TFC
73TF
194.7TFC
0MGOCAPPED LATERAL 9 O'CLOCK @ MH
327.2AMH01 0163
0MWM
33.4TF
244.8TF
46TFC
250.6TF
222.5TF
327.1MGOLATERAL AT MH 3 OCLOCK
169.2TF
138.8TFC
137TF
270.4TFC
120.6TFC
119.3TB
171.7TFC
298.6TFC
0MGOLATERAL AT MH 3 OCLOCK
100.7TB
297TFC
123.8TF
0MWL
197.2TF
327.1MGOLATERAL AT MH 9 OCLOCK
243.1CL

Properties (5)

additional_info
SC306169
custom_field_two
4
customer
LACSD
datetime
2016-09-06T04:45:54-07:00
sewer_category
Gravity