Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 29, 2016, 11:13 AM
  • 01 0201_01 0200_29082016_025425.mp4

Date
08/29/2016
W/O
585995
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01243
Time
4:13 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3574
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
WO_585995_TV01012_AUG2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0201
Downstream MH
01 0200
Dir. of Survey
Downstream
Length Surveyed
312.6 ft.
Total Length
312.7 ft.
Structural Index
3
Structural Quick
3624
Structural Rating
26
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
26
Pipe schematic from manhole 01 0201 to 01 0200
MH: 01 0201MH: 01 0200downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 02016.1 ft. CM - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES30 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"35.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"53.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"95.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"103.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"116.8 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES119.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES128.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES145 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"175.7 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES183.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"191.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"213.8 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES225.6 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES233.4 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"241.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"248.4 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES269.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES284.4 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES285.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"297.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"312.7 ft. AMH - Downstream Manhole, Survey Ends - 01 0200312.7 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK

Observation photos (10)

  • Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

    6.1 ft. - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    116.8 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    119.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    128.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    175.7 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    213.8 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    225.6 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    248.4 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    269.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    284.4 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

Observations (27)

DistanceCodeObservation
233.4TFA
116.8CM
128.6CM
297.6TF
183.1TF
119.4CM
312.7AMH01 0200
145TF
30TF
191.7TFC
53.2TF
241.5TF
312.7MGOLATERAL AT MH 9 OCLOCK
225.6CM
269.2CL
103.6TF
0MWM
248.4CL
6.1CM
0MWL
213.8CL
95.3TFC
285.9TFC
284.4CL
35.4TF
175.7CM
0AMH01 0201

Properties (5)

additional_info
SC306162
custom_field_two
3
customer
LACSD
datetime
2016-08-29T04:13:36-07:00
sewer_category
Gravity