Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 8, 2016, 06:33 AM
  • 02 0344A_02 0344 _070716_233419.mp4

Date
07/07/2016
W/O
574757
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00259
PipeID
P02657
Time
11:33 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3562
Sewer Name
02 EAST COMPTON BOULEVARD RELIEF TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
36
Purpose
Routine Assessment
Project
WO_574757_TV02059_JUNE2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0344A
Downstream MH
02 0344
Dir. of Survey
Downstream
Length Surveyed
245.7 ft.
Total Length
245.7 ft.
Structural Index
3
Structural Quick
3300
Structural Rating
9
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 02 0344A to 02 0344
MH: 02 0344AMH: 02 0344downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 02 0344A0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area4.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES11 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES16 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start242.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish245.7 ft. AMH - Downstream Manhole, Survey Ends - 02 0344

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    4.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    11 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    16 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
242.9CM
16CM
245.7AMH02 0344
0MGOCONNECTION AT THE MH 9 OC'LOCK
0AMH02 0344A
0MWL
0MWM
4.5CM
11CM

Properties (5)

additional_info
SC305868
custom_field_two
3
customer
LACSD
datetime
2016-07-07T23:33:48-07:00
sewer_category