Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2016, 10:41 AM
  • A 0397A 0396District 02_072616.mp4

Date
07/26/2016
W/O
574384
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00325
PipeID
P08307
Time
3:41 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3663
Sewer Name
A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
City
SAN GABRIEL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
01
Purpose
Routine Assessment
Project
WO_574384_TV02187_JUNE2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
A 0397
Downstream MH
A 0396
Dir. of Survey
Downstream
Length Surveyed
489.8 ft.
Total Length
489.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole A 0397 to A 0396
MH: A 0397MH: A 0396downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 03970 ft. MWM - Water Mark, 20 %of cross sectional area6.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start486.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish489.8 ft. AMH - Downstream Manhole, Survey Ends - A 0396

Observation photos (3)

  • Water Mark, 20 %of cross sectional area

    0 ft. - Water Mark, 20 %of cross sectional area

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    6.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Finish

    486.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observations (6)

DistanceCodeObservation
489.8AMHA 0396
0MWL
6.8DAGS
486.3DAGS
0AMHA 0397
0MWM

Properties (6)

additional_info
SC305542
custom_field_two
4
customer
LACSD
datetime
2016-07-26T03:41:58-07:00
sewer_category
GRAVITY
year_laid
19810109