Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 20, 2016, 10:02 AM
  • 05 1642_05 1641 _062016_030418.mp4

Date
06/20/2016
W/O
563400
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00539
PipeID
P06865
Time
3:02 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3400
Sewer Name
05 WEST TORRANCE TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
WO_563400_TV05275_JUNE2016
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1641
Downstream MH
05 1642
Dir. of Survey
Upstream
Length Surveyed
273.7 ft.
Total Length
273.7 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
156
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
156
Pipe schematic from manhole 05 1641 to 05 1642
MH: 05 1641MH: 05 1642upstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 CAPPED O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 05 16420 ft. MGO - General Observation - CONNECTION AT THE MH CAPPED 3 O'CLOCK5.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish38.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"105.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"157.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"161.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"207.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"258.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"267.9 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start273.7 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK273.7 ft. AMH - Downstream Manhole, Survey Begins - 05 1641273.7 ft. MWM - Water Mark, 30 %of cross sectional area273.7 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (1)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
0MGOCONNECTION AT THE MH 9 O'CLOCK
15.5TFC
66.3TFC
273.7MGOCONNECTION AT THE MH 9 CAPPED O'CLOCK
273.7AMH05 1642
273.7MGOCONNECTION AT THE MH CAPPED 3 O'CLOCK
5.8CM
235.5TF
0AMH05 1641
268.2CM
168TFC
112.4TF
116.2TFC
0MWM
0MWL

Properties (5)

additional_info
SC300400
custom_field_two
3
customer
LACSD
datetime
2016-06-20T03:02:30-07:00
sewer_category
Gravity