- Date
- 06/20/2016
- W/O
- 563400
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00539
- PipeID
- P06861
- Time
- 4:23 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3400
- Sewer Name
- 05 WEST TORRANCE TRUNK
- City
- TORRANCE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- WO_563400_TV05275_JUNE2016
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 05 1638
- Downstream MH
- 05 1637
- Dir. of Survey
- Downstream
- Length Surveyed
- 230.7 ft.
- Total Length
- 230.7 ft.
- Structural Index
- 3
- Structural Quick
- 3G00
- Structural Rating
- 114
- O&M Index
- 1
- O&M Quick
- 1100
- O&M Rating
- 1
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 115
Pipe schematic from manhole 05 1638 to 05 1637 Observation photos (4)

38.4 ft. - Roots Fine Lateral, at 12 o'clock

40.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

58.3 ft. - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"

75.4 ft. - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"