Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2017, 08:11 AM
  • Section#1_05 2082_05 2081__892017__G6797.mp4

Date
08/09/2017
W/O
0635654
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00456
PipeID
P07225
Time
1:11 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6797
Sewer Name
05 HAWTHORNE-LAWNDALE-TORRANCE TRUNK
City
HAWTHORNE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Capital Improvement Program Assesment
Project
20170809MDM_HAWTHORNE_LAWNDALE_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Upstream MH
05 2082
Downstream MH
05 2081
Dir. of Survey
Downstream
Length Surveyed
738.7 ft.
Total Length
738.7 ft.
Structural Index
3
Structural Quick
3]00
Structural Rating
450
O&M Index
2
O&M Quick
2\00
O&M Rating
292
Overall Index
3
Overall Quick
Overall Rating
742
Pipe schematic from manhole 05 2082 to 05 2081
MH: 05 2082MH: 05 2081downstream0 ft. AMH - Upstream Manhole, Survey Begins - 4:55AM0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. MGO - General Observation - MAG COAT 60% START 8:00 TO 2:00 START10.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start208.7 ft. MGO - General Observation - OLD MAG COAT 70% START208.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG310.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG418.2 ft. MGO - General Observation - MAG COAT 80% START ,OLD607.4 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG738.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish738.2 ft. MGO - General Observation - MAG COAT 80 FINISH738.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG738.7 ft. AMH - Downstream Manhole, Survey Ends - 5:50AM

Observation photos (8)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MAG COAT 60% START 8:00 TO 2:00 START

    2 ft. - General Observation - MAG COAT 60% START 8:00 TO 2:00 START

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    10.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - OLD MAG COAT 70% START

    208.7 ft. - General Observation - OLD MAG COAT 70% START

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    208.7 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    310.7 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • General Observation - MAG COAT 80% START ,OLD

    418.2 ft. - General Observation - MAG COAT 80% START ,OLD

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    607.4 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

Observations (15)

DistanceCodeObservation
738.7AMH5:50AM
10.3DAGS
0AMH4:55AM
738.2DAGS
607.4SAPSEVERE AGG
0MWL
2SAPSEVERE AGG
738.2MGOMAG COAT 80 FINISH
2MGOMAG COAT 60% START 8:00 TO 2:00 START
310.7SAPSEVERE AGG
738.2SAPSEVERE AGG
0MWM
208.7MGOOLD MAG COAT 70% START
208.7SAPSEVERE AGG
418.2MGOMAG COAT 80% START ,OLD

Properties (5)

custom_field_three
SEVERE AGG PROJECTING-SMALL AREAS POSSIBLE REBAR
custom_field_two
3
customer
LACSD
datetime
2017-08-09T01:11:23-07:00
year_laid
19731002