- Date
- 05/25/2017
- W/O
- 635497
- Weather
- Dry
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00546
- PipeID
- P07391
- Time
- 11:57 PM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4271
- Sewer Name
- 05 104TH STREET TRUNK
- City
- LOS ANGELES
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- WO_635497_TV05028_MAY2017
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 05 2265
- Downstream MH
- 05 2264A
- Dir. of Survey
- Downstream
- Length Surveyed
- 327.5 ft.
- Total Length
- 327.5 ft.
- Structural Index
- 3
- Structural Quick
- 4122
- Structural Rating
- 8
- O&M Index
- 2
- O&M Quick
- 2611
- O&M Rating
- 13
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 21
Pipe schematic from manhole 05 2265 to 05 2264A Observation photos (4)

2.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

8.5 ft. - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES

176.7 ft. - Broken, from 12 to 02 o'clock, within 8 inches of joint: YES - WITH REPAIR

266.8 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES