Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 26, 2017, 07:45 AM
  • 05 2264_05 2263_20170526_010021.mp4

Date
05/26/2017
W/O
635497
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00546
PipeID
P07390
Time
12:45 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4271
Sewer Name
05 104TH STREET TRUNK
City
LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
09
Purpose
Routine Assessment
Project
WO_635497_TV05028_MAY2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 2264
Downstream MH
05 2263
Dir. of Survey
Downstream
Length Surveyed
274.7 ft.
Total Length
274.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2611
O&M Rating
13
Overall Index
2
Overall Quick
Overall Rating
13
Pipe schematic from manhole 05 2264 to 05 2263
MH: 05 2264MH: 05 2263downstream0 ft. MGO - General Observation - MH ABANDONED0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 2264 ABANDONED2.1 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start4.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4"50.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4"96.3 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"146.4 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"186.9 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"227.1 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"267 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"271.5 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish274.7 ft. AMH - Downstream Manhole, Survey Ends - 05 2263274.7 ft. VC - Vermin Cockroach, within 8 inches of joint: NO

Observation photos (1)

  • Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
4.5TB
274.7AMH05 2263
0MGOMH ABANDONED
186.9TBC
146.4TBC
0MWM
227.1TBC
2.1DAGS
96.3TBC
271.5DAGS
50.7TB
267TBC
0MWL
274.7VC
0AMH05 2264 ABANDONED

Properties (4)

additional_info
SC345271
custom_field_two
4
customer
LACSD
datetime