- Date
- 07/27/2017
- W/O
- 0653811
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00151
- PipeID
- P22777
- Time
- 8:28 AM
- Certificate
- U-415-06024039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Jetting
- Media Label
- G7470
- Sewer Name
- D JOINT OUTFALL D - UNIT 2A
- City
- TORRANCE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 27
- Purpose
- Maintenance Related
- Project
- 20170727DF_JOUINT_OUTFALL_D_UNIT_2A
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 57 in.
- Upstream MH
- D 0024
- Downstream MH
- A 0961
- Dir. of Survey
- Downstream
- Length Surveyed
- 150.4 ft.
- Total Length
- 150.4 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 5
Pipe schematic from manhole D 0024 to A 0961 Observation photos (10)

83.5 ft. - General Photograph - START OF POSSIBLE SINKHOLE

90.6 ft. - General Photograph - MIDDLE SINKHOLE AREA

95.7 ft. - General Photograph - MIDDLESINKHOLE AREA

100.8 ft. - General Photograph - MIDDLE SINKHOLE AREA

105.5 ft. - General Photograph - MIDDLE SINKHOLE AREA

110.3 ft. - General Photograph - MIDDLE SINKHOLE AREA

116 ft. - General Photograph - END OF POSSIBLE SINKHOLE

129.5 ft. - General Photograph

135 ft. - General Photograph

150.4 ft. - General Photograph