- Date
- 07/21/2017
- W/O
- 0652858
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00225
- PipeID
- P02181
- Time
- 9:13 AM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7465
- Sewer Name
- 01 WILCOX AVENUE TRUNK
- City
- SOUTH GATE
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- 20170721SHO_WILCOX_AVENUE_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 01 1150
- Downstream MH
- H 0077
- Dir. of Survey
- Downstream
- Length Surveyed
- 400.7 ft.
- Total Length
- 400.7 ft.
- Structural Index
- 3
- Structural Quick
- 3300
- Structural Rating
- 9
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 13
Pipe schematic from manhole 01 1150 to H 0077 Observation photos (5)

343.9 ft. - Surface Aggregate Visible, from 11 to 02 o'clock, within 8 inches of joint: YES

363.2 ft. - Surface Aggregate Visible, from 09 to 01 o'clock, within 8 inches of joint: YES

393.6 ft. - Surface Aggregate Visible, from 12 to 02 o'clock, within 8 inches of joint: YES - ALSO SPALLING FROM 12 TO 3

400.7 ft. - General Photograph - ZOOMED IN

400.7 ft. - General Photograph - ZOOMED OUT