Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2017, 08:51 AM
  • 15 0614_15 0613A_042717_015127.mp4

Date
04/27/2017
W/O
630380
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00601
PipeID
P24099
Time
1:51 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4478
Sewer Name
15 DOUBLE AVENUE TRUNK
City
ARCADIA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_630380_TV15205_APR2017
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0614
Downstream MH
15 0613A
Dir. of Survey
Downstream
Length Surveyed
230.7 ft.
Total Length
230.7 ft.
Structural Index
3
Structural Quick
3Q00
Structural Rating
273
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
277
Pipe schematic from manhole 15 0614 to 15 0613A
MH: 15 0614MH: 15 0613Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 06140 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2.2 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES2.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start14.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"47.3 ft. RBL - Roots Ball Lateral, at 02 o'clock, 55 %47.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"74.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"98.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"125.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"146.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"148.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish148.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start221.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"224 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"230.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish230.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK230.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish230.7 ft. AMH - Downstream Manhole, Survey Ends - 15 0613A230.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (4)

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    2.2 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    148.7 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (22)

DistanceCodeObservation
0AMH15 0614
230.7AMH15 0613A
14.3TFC
224TF
230.6CM
230.7MGOCONNECTION AT MH 3 O'CLOCK
221.3TF
125.5TFA
0MWM
47.3RBL
230.6MGOCONNECTION AT MH 9 O'CLOCK
146.5TF
2.2CM
47.3TFA
74.2TF
6.8CM
148.7SAP
0MWL
2.2SAV
230.6SAP
148.6SAV
98.8TF

Properties (5)

additional_info
SC345188
custom_field_two
3
customer
LACSD
datetime
2017-04-27T01:51:06-07:00
sewer_category