Wastewater/Activity/PacpInspection/1.0Mar 6, 2017, 12:33 PM
  • 18 1099_18 1098 _03062017_043343.mp4

Date
03/06/2017
W/O
624500
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00699
PipeID
P14265
Time
4:33 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4366
Sewer Name
18 SANTA FE STREET RELIEF TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_624500_TV18084_MAR2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 1099
Downstream MH
18 1098
Dir. of Survey
Downstream
Length Surveyed
643.9 ft.
Total Length
643.9 ft.
Structural Index
3
Structural Quick
423F
Structural Rating
119
O&M Index
2
O&M Quick
312Y
O&M Rating
259
Overall Index
2
Overall Quick
Overall Rating
378
Pipe schematic from manhole 18 1099 to 18 1098
MH: 18 1099MH: 18 1098downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 10990 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start402.7 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES433 ft. FS - Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES463.5 ft. CM - Crack Multiple, from 12 to 06 o'clock, within 8 inches of joint: YES468.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start636.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish636.3 ft. FM - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES641.2 ft. ID - Infiltration Dripper, at 03 o'clock, within 8 inches of joint: YES641.2 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES643.9 ft. AMH - Downstream Manhole, Survey Ends - 18 1098643.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (8)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    402.7 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

    433 ft. - Fracture Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 06 o'clock, within 8 inches of joint: YES

    463.5 ft. - Crack Multiple, from 12 to 06 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    468.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    636.3 ft. - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 03 o'clock, within 8 inches of joint: YES

    641.2 ft. - Infiltration Dripper, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    641.2 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
0MWM
463.5CM
636.3CM
2DAGS
402.7CM
433FS
0AMH18 1099
641.2ID
641.2FM
636.3FM
643.9AMH18 1098
468.5CM
0MWL
643.9DAGS

Properties (5)

additional_info
SC306963
custom_field_two
3
customer
LACSD
datetime
2017-03-06T04:33:24-08:00
year_laid
26802