Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 21, 2017, 08:41 AM
  • 01 0431_01 0430A_21032017_014232.mpg

Date
03/21/2017
W/O
624631
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00208
PipeID
P00913
Time
1:41 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4389
Sewer Name
01 HOLMES-WILLOWBROOK TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
WO_624631_TV01248_MAR2017
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0431
Downstream MH
01 0430A
Dir. of Survey
Downstream
Length Surveyed
142.6 ft.
Total Length
142.6 ft.
Structural Index
3
Structural Quick
3D2B
Structural Rating
115
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
115
Pipe schematic from manhole 01 0431 to 01 0430A
MH: 01 0431MH: 01 0430Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 04310 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area4.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start8.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"24.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"32.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"49 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"53.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start58.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"76.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"85 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"103.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"106.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"111.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"129.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"140.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish140.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish142.6 ft. AMH - Downstream Manhole, Survey Ends - 01 0430A142.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    53.8 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (21)

DistanceCodeObservation
140.6SAV
140.5CL
8.8TF
32.8TFC
106.9TFC
0AMH01 0431
0MWM
76.4TFC
53.8CL
85TFC
142.6AMH01 0430A
4.2SAV
24.1TFC
103.2TF
58.4TFC
49TFC
111.9TFC
142.6MGOCONNECTION AT MH 3 O'CLOCK
0MGOCONNECTION AT MH 3 O'CLOCK
0MWL
129.9TFC

Properties (5)

additional_info
SC306898
custom_field_two
3
customer
LACSD
datetime
2017-03-21T01:41:59-07:00
sewer_category
Gravity