Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 11, 2017, 06:39 AM
  • 01 0795_01 0794_10042017_233948.mp4

Date
04/10/2017
W/O
630043
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00197
PipeID
P01497
Time
11:39 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4424
Sewer Name
01 BULLIS ROAD-TEMPLE STREET TRUNK
City
LYNWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
17
Purpose
Routine Assessment
Project
WO_630043_TV01008_APR2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0795
Downstream MH
01 0794
Dir. of Survey
Downstream
Length Surveyed
214.3 ft.
Total Length
214.3 ft.
Structural Index
4
Structural Quick
4G00
Structural Rating
168
O&M Index
2
O&M Quick
412G
O&M Rating
88
Overall Index
3
Overall Quick
Overall Rating
256
Pipe schematic from manhole 01 0795 to 01 0794
MH: 01 0795MH: 01 0794downstream0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 07950 ft. MWM - Water Mark, 65 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start2.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start45.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"79.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"93.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"118.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"142.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"176.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"184.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"212.5 ft. MGO - General Observation - COCKROACHES IN MANHOLE212.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish212.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish214.3 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK214.3 ft. AMH - Downstream Manhole, Survey Ends - 01 0794

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    212.5 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (17)

DistanceCodeObservation
214.3MGOACTIVE CONNECTION AT MH 3 O'CLOCK
184.6TFC
79.5TFC
0MWL
93.9TFC
0AMH01 0795
142.7TFC
45.6TFC
212.5MGOCOCKROACHES IN MANHOLE
212.5FM
118.3TFC
0MWM
212.5DAGS
214.3AMH01 0794
2.1FM
176.2TFC
2DAGS

Properties (5)

additional_info
SC306993
custom_field_two
3
customer
LACSD
datetime
2017-04-10T23:39:18-07:00
sewer_category
Gravity