- Date
- 04/18/2017
- W/O
- 630156
- Weather
- Dry
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00677
- PipeID
- P14877
- Time
- 2:40 AM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4267
- Sewer Name
- 18 LA HABRA HEIGHTS TRUNK, SECTION 1
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 22
- Purpose
- Routine Assessment
- Project
- WO_630156_TV18008_APR2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 18 1023
- Downstream MH
- 18 1022
- Dir. of Survey
- Downstream
- Length Surveyed
- 133.9 ft.
- Total Length
- 133.9 ft.
- Structural Index
- 4
- Structural Quick
- 4100
- Structural Rating
- 4
- O&M Index
- 2
- O&M Quick
- 2D11
- O&M Rating
- 53
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 57
Pipe schematic from manhole 18 1023 to 18 1022 Observation photos (3)

2.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

133.9 ft. - Survey Abandoned - DEFORMED LINER TRACTOR FLIPS OVER

133.9 ft. - Deformed, 10 % - LINER