55.6 ft. - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES
104.5 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES
122.9 ft. - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start
153.1 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"
229.5 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"
297 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 185.2 | TFA | — |
| 111.1 | TB | — |
| 105.6 | TB | — |
| 0 | AMH | 15 0573 |
| 0 | MWL | — |
| 302.6 | DSZ | — |
| 55.6 | DSZ | — |
| 297 | DAGS | — |
| 302.6 | AMH | 15 0572 |
| 302.6 | MGO | CONNECTION AT MH 3 O'CLOCK |
| 153.1 | TBI | — |
| 122.9 | DSZ | — |
| 104.5 | CL | — |
| 4.3 | TF | — |
| 0 | MWM | — |
| 229.5 | TBI | — |