Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 8, 2017, 06:38 AM
  • 15 0868_15 0732 _08062017_005437.mp4

Date
06/07/2017
W/O
640598
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00616
PipeID
P12661
Time
11:38 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4544
Sewer Name
15 MONROVIA OUTFALL TRUNK
City
MONROVIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
09
Purpose
Routine Assessment
Project
WO_640598_TV15132_JUN2017
Material
NRCP
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
15 0732
Downstream MH
15 0868
Dir. of Survey
Upstream
Length Surveyed
198.2 ft.
Total Length
198.2 ft.
Structural Index
3
Structural Quick
3G00
Structural Rating
117
O&M Index
2
O&M Quick
2G11
O&M Rating
81
Overall Index
2
Overall Quick
Overall Rating
198
Pipe schematic from manhole 15 0732 to 15 0868
MH: 15 0732MH: 15 0868upstream0 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO - DEBRIS0 ft. MSA - Survey Abandoned - DEBRI0.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish196.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start196.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start196.2 ft. VC - Vermin Cockroach196.2 ft. MGO - General Observation - MAG COATING198.2 ft. MGO - General Observation - CONNECTION AT 9 OC198.2 ft. AMH - Downstream Manhole, Survey Begins - 15 0732198.2 ft. MWM - Water Mark, 45 %of cross sectional area198.2 ft. MWL - Water Level, 40 %of cross sectional area

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0MGOCONNECTION AT 9 OC
198.1SAV
0AMH15 0732
0MWM
198.2DSZDEBRIS
2DAGS
198.2MSADEBRI
2SAV
198.1DAGS
2VC
2MGOMAG COATING
0MWL

Properties (5)

additional_info
SC345359
custom_field_two
5
customer
LACSD
datetime
2017-06-07T23:38:41-07:00
sewer_category
Gravity