- Date
- 05/26/2017
- W/O
- 619148
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00593
- PipeID
- P12991
- Time
- 1:33 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4563
- Sewer Name
- 15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
- City
- ARCADIA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- WO_619148_TV15202_MAY2017
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 15 0790
- Downstream MH
- 15 0789
- Dir. of Survey
- Downstream
- Length Surveyed
- 99 ft.
- Total Length
- 99 ft.
- Structural Index
- 2
- Structural Quick
- 322C
- Structural Rating
- 44
- O&M Index
- 2
- O&M Quick
- 2C00
- O&M Rating
- 38
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 82
Pipe schematic from manhole 15 0790 to 15 0789 Observation photos (3)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

6.4 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

94.6 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start