Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 24, 2017, 10:11 AM
  • 15 0748_15 0747 _24052017_031141.mp4

Date
05/24/2017
W/O
619148
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00593
PipeID
P12948
Time
3:11 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4561
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
09
Purpose
Routine Assessment
Project
WO_619148_TV15202_MAY2017
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0748
Downstream MH
15 0747
Dir. of Survey
Downstream
Length Surveyed
348.2 ft.
Total Length
348.2 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
207
O&M Index
2
O&M Quick
2M00
O&M Rating
138
Overall Index
3
Overall Quick
Overall Rating
345
Pipe schematic from manhole 15 0748 to 15 0747
MH: 15 0748MH: 15 0747downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 07482 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start24.3 ft. MGO - General Observation - MAG COATING 40%112.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"165 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"262 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"307.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"332.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"346.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish346.3 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish346.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE348.2 ft. AMH - Downstream Manhole, Survey Ends - 15 0747348.2 ft. MGO - General Observation - ACTIVE CONNECTIONS AT MH 3 O'CLOCK

Observation photos (2)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
348.2AMH15 0747
307.6TFA
112.6TFA
262TF
2SAV
0MWM
332.2TF
0MWL
348.2MGOACTIVE CONNECTIONS AT MH 3 O'CLOCK
346.3DAGS
0AMH15 0748
346.3SAV
2DAGS
165TF
346.3MGOCOCKROACHES IN MANHOLE
24.3MGOMAG COATING 40%

Properties (5)

additional_info
SC345237
custom_field_two
3
customer
LACSD
datetime
2017-05-24T03:11:27-07:00
sewer_category