Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 18, 2017, 10:31 AM
  • 15 0550_15 0549 _18042017_021835.mp4

Date
04/18/2017
W/O
630147
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00629
PipeID
P12479
Time
3:31 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4469
Sewer Name
15 SANTA ANITA OUTFALL TRUNK
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_630147_TV15085_APR2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0550
Downstream MH
15 0549
Dir. of Survey
Downstream
Length Surveyed
417.2 ft.
Total Length
417.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0550 to 15 0549
MH: 15 0550MH: 15 0549downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 055017.4 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"23.2 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"83.5 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"112 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"142 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"146.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"194.7 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"254.7 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"281.7 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"293.4 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"336.3 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"346.1 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 6"417.2 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK417.2 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK417.2 ft. AMH - Downstream Manhole, Survey Ends - 15 0549

Observations (18)

DistanceCodeObservation
194.7TB
0MWM
142TB
281.7TB
17.4TB
336.3TB
146.7TB
0MWL
83.5TB
254.7TB
112TB
293.4TB
0AMH15 0550
417.2MGOCONNECTION AT MH 3 O'CLOCK
417.2MGOCONNECTION AT MH 12 O'CLOCK
23.2TB
346.1TB
417.2AMH15 0549

Properties (5)

additional_info
SC345178
custom_field_two
4
customer
LACSD
datetime
2017-04-18T03:31:37-07:00
sewer_category
Gravity