Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 18, 2017, 04:38 AM
  • 15 0561_15 0560 _17042017_213845.mp4

Date
04/17/2017
W/O
630147
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00629
PipeID
P12490
Time
9:38 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4469
Sewer Name
15 SANTA ANITA OUTFALL TRUNK
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
08
Purpose
Routine Assessment
Project
WO_630147_TV15085_APR2017
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0561
Downstream MH
15 0560
Dir. of Survey
Downstream
Length Surveyed
371.1 ft.
Total Length
371.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 15 0561 to 15 0560
MH: 15 0561MH: 15 0560downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 05610 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area10.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: YES38.7 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"55.9 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"64 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"149.5 ft. TS - Tap Saddle, at 09 o'clock, -, within 8 inches of joint: NO, 6"176.7 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"283.8 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"303.8 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"371.1 ft. AMH - Downstream Manhole, Survey Ends - 15 0560

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 04 o'clock,  , within 8 inches of joint: YES

    10.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: YES

  • Tap Saddle, at 09 o'clock, -, within 8 inches of joint: NO, 6"

    149.5 ft. - Tap Saddle, at 09 o'clock, -, within 8 inches of joint: NO, 6"

Observations (12)

DistanceCodeObservation
176.7TB
149.5TS
371.1AMH15 0560
64TB
38.7TB
0AMH15 0561
0MWM
283.8TB
55.9TB
10.8DAGS
0MWL
303.8TB

Properties (5)

additional_info
SC345178
custom_field_two
4
customer
LACSD
datetime
2017-04-17T21:38:24-07:00
sewer_category
Gravity