- Date
- 03/10/2017
- W/O
- 624624
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00488
- PipeID
- P06329
- Time
- 2:12 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4377
- Sewer Name
- 05 MONETA EXTENSION TRUNK, SECTION 1
- City
- GARDENA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- WO_624624_TV05328_MAR2017
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 05 1095
- Downstream MH
- 05 1094
- Dir. of Survey
- Downstream
- Length Surveyed
- 325.1 ft.
- Total Length
- 325.1 ft.
- Structural Index
- 3
- Structural Quick
- 3J23
- Structural Rating
- 174
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 174
Pipe schematic from manhole 05 1095 to 05 1094 Observation photos (6)

6 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

19.4 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

40.7 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

49.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

59.1 ft. - Fracture Circumferential, from 07 to 09 o'clock, within 8 inches of joint: YES

193.7 ft. - Fracture Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES